Acessibilidade / Reportar erro

Comparison of overall heat loss coefficient to warm greenhouse applying energy saving techiniques

The Global Heat Loss Coefficient (U) allows some answers about thermal requirements of climatic greenhouse. This trial determined this coefficient for a greenhouse in Madrid (Spain) where night measurements of inside and outside air temperature as well as energy consumption to heat were used. Comparisons were accomplished among the used heating techniques as: radiant floor and heat fan combined with two techniques aiming to promote a better thermal which means the use of a plastic covering forming a double couple or the use of a plastic tunnel. The lowest coefficients for the use of radiant soil with tunnel and heat fan with double couple were respectively 7.19 W m-2 ºC-1 and 9.11 W m-2 ºC-1 and the largest value was 15.13 W m-2 ºC-1 for the heat fan use without plastics. Therefore, the results registered best thermal efficiency for the tested techniques.

climate systems; energy saving; greenhouse


Associação Brasileira de Engenharia Agrícola SBEA - Associação Brasileira de Engenharia Agrícola, Departamento de Engenharia e Ciências Exatas FCAV/UNESP, Prof. Paulo Donato Castellane, km 5, 14884.900 | Jaboticabal - SP, Tel./Fax: +55 16 3209 7619 - Jaboticabal - SP - Brazil
E-mail: revistasbea@sbea.org.br