Acessibilidade / Reportar erro

Evaluation of susceptibility of hydrogen induced cracking in microalloyed armor steel welds using a geometry modified implant test

The Hydrogen Induced Cracking (HIC) susceptibility of 4,5mm thickness quenched and tempered (Q&T) armor plate steel welding joints was evaluated. The joints were obtained using low heat input and SMAW process with 2,4 mm AWS E11018M electrode. The HIC susceptibility was evaluated using a geometry modified implant test for thin plates. The joints studied were produced with and without preheating and using welding electrodes with and without exposure to atmospheric conditions. The HIC resistance was severely impaired by improperly storage while preheating conditions did not preclude HIC.

Armor plates; Hydrogen Induced Cracking; Implant Test


Associação Brasileira de Soldagem Rua Dr Guilherme Bannitz, 126 conj 42, 04532-060 - São Paulo/SP Brasil, Tel.: (55 11) 3045 5040, Fax: (55 11) 3045 8578 - São Paulo - SP - Brazil